
Add to Cart
LED Display 200AH SEPS 350W Off Grid Solar Power Systems
Feature:
◆ Pure sine wave output.
◇ AVR function, AC charge.
◆ LCD & LED integration display
◇ AC first and battery first optional
◆ Inverter, controller and battery are all in one cabinet.
◇ Protection: Low voltage, over voltage, short circuit,over
load and over temperature etc.
Product Specification:
Specification | ||||
Model SEPS | 35112 | |||
Rated Power | 350W | |||
Peak Power(20ms) | 1050W | |||
Start Motor | 0.3HP | |||
Battery Voltage | 12VDC | |||
Inside Battery Capacity | 200Ah*1 | |||
Size(L*W*Hmm) | 600*300*495 | |||
Package Size (L*W*Hmm) | 660*360*620 | |||
N.W.(kg) Without Battery | 23 | |||
G.W.(kg) Without Battery Carton Packing | 26 | |||
Installation Method | Tower | |||
Parameter | ||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||
AC Input Voltage Range | 73VAC~138VAC / 145VAC~275VAC | |||
AC Input Frequency Range | 45Hz~65Hz | |||
Max AC charging current | 6A~15A (Depending on the model) | |||
AC charging voltage | LEAD battery:Charge Voltage :14V; Float Voltage:13.8V(Single battery voltage) | |||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||
Output | Efficiency(Battery Mode) | ≥85% | ||
Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2% | |||
Output Frequency(Battery Mode) | 50/60Hz±1% | |||
Output Wave(Battery Mode) | Pure Sine Wave | |||
Efficiency(AC Mode) | >99% | |||
Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% | |||
Output Frequency(AC Mode) | Tracking Automatically | |||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | |||
No load loss(Battery Mode) | ≤1% rated power | |||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||
No load loss(Energy saving Mode) | ≤10W | |||
Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | ||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | ||
Battery undervoltage protection | 10.5V(Single battery voltage) | |||
Battery overvoltage alarm | 15V(Single battery voltage) | |||
Battery overvoltage protection | 17V(Single battery voltage) | |||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | |||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
Temperature protection | >90°C(Shut down output) | |||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||
Inside Solar controller (Optional) | Charging Mode | MPPT or PWM | ||
Charging current | 10A/20A/30A/40A/50A/60A | |||
PV Input Voltage Range | PWM: 15V-44V / MPPT: 15V-120V | |||
Max PV Input Voltage (At the lowest temperature) | PWM: 50V / MPPT: 150V | |||
PV Array Maximum Power | 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A) | |||
Standby loss | ≤3W | |||
Maximum conversion efficiency | >95% | |||
Working Mode | Battery First/AC First/Saving Energy Mode | |||
Transfer Time | ≤4ms | |||
Display | LCD | |||
Thermal method | Cooling fan in intelligent control | |||
Communication | RS232(Optional) | |||
Environment | Operating temperature | -10℃~40℃ | ||
Storage temperature | -15℃~60℃ | |||
Noise | ≤55dB | |||
Elevation | 2000m(More than derating) | |||
Humidity | 0%~95% ,No condensation | |||
Warranty | 1 year |